What is the cause of the error when measuringthe thermocouple

Jan 24, 2018

What is the cause of the error when measuring the thermocouple?

What is the cause of the error when measuring the thermocouple?

Domestic thermocouple measurement error reasons: improper installation of the introduction of the error: the installation of the instrument is also an important part of our emphasis on the installation is not good not only affect the measurement accuracy may also reduce the service life, such as thermocouple installation and insertion depth can not reflect The true temperature of the furnace, etc. In other words, the thermocouple should not be placed too close to the door and heated place, insert the depth of at least 8 to 10 times the diameter of the protective tube; thermocouple protection between the casing and the interval The thermocouple protection pipe and the hole between the furnace wall hole between the application of refractory mud or asbestos rope and other insulating material block to avoid hot and cold air convection affect the accuracy of temperature measurement; thermoelectricity The thermocouple should be installed as far as possible to avoid the strong magnetic field and strong electric field, so the thermocouple and power cable should not be installed in the same catheter to avoid the introduction of interference caused by error; thermoelectric Even can not be installed in the area where the measured medium is rarely flowing, when measuring the temperature of the tube with a thermocouple, it is necessary to make the thermocouple against the flow Speed direction of installation, and full contact with the gas.

    What is the type of connection? What is the focus of the product selection? How to install the measurement data is accurate? Thermocouple structure is simple, but still in use there will be a variety of problem. For example: improper installation or use, will lead to a larger measurement error, and even test qualified thermocouple will be due to improper operation, in the use of unqualified, in the carburizing and other reducing atmosphere, if not pay attention, K type Thermocouples are also poor due to selective oxidation. In order to improve the measurement accuracy, reduce the measurement error, extend the service life of the thermocouple, requiring users not only should have the instrument operation skills, but also should have the physical, chemical and material and other knowledge. Thermocouple measurement materials are different, different materials measurement range is different, the product selection requires the user to provide the highest measurement temperature and commonly used temperature measurement, as well as the measurement accuracy requirements to determine what materials used thermocouple.


Send Inquiry